1a. ACI: Chromatography \ Mass Spectrometry: ACI: 930/863 Metrohm Compact, CIC/Cation IC
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Ion-exchange chromatography is a technique for the separation and determination of ionic compounds.
Manufacturer: Metrohm
Model Name: 930/863 Metrohm Compact
Applications: Analysis of ionic compounds
Instrument Overview: Combustion Ion Chromatography (CIC) extends the range of ion chromatography to all types of combustible samples. The focus here is primarily on the simultaneous determination of the various halogens and sulfur in widely differing matrices.
Technical features and specifications:
Sample Type: Solid / Liquid
Determination of Halogens and Sulphur
Charges: NA
Instrument Manufacturer URL:
https://www.metrohm.com/en-us/products-overview/ion_chromatography/hyphenated%20techniques#CIC
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Agilent, GC-MSD-PY, GC8890/MS5977C/PY-3030D
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Agilent, GCxGC, GC8890/MS5977C/FID
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Agilent, GPC w Triple Det Array
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
GPC/SEC Unit: Agilent; Detector Units: Wyatt
Manufacturer: GPC: 1260 Infinity II; MALS: Dawn 8, RID: OptiLab, Viscometer: ViscoStar
Model Name: This system equipped with Triple Detector Array, which can provide a more comprehensive polymer analyses with broad molecular size ranges and higher resolution, predominantly for polymeric materials with complex architecture that exhibit anisotropic light scattering behaviors, without reliance on conventional column calibrations.
Applications: NA
Instrument Overview: Molecular Weight Range: ~ 102 Da to 107 Da; Radius of gyration (Rg) Range: 10 nm to 150 nm; MALS detection angles: Eight; Provide measurement of absolute molecular weight and molecular weight distribution of polymers and macromolecules.
Technical features and specifications:
Gel Permeation/Size Exclusion Chromatography for polymer MW and size measurements
Charges:
NA
Instrument Manufacturer URL: NA
Detailed Specifications:
NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Agilent, RGC-GC with Grab Sampling Option
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Altamira, TPDRO Analyzer coupled with MS
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Anton Paar, Microwave Digester, 7501
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Esco, Shaker Incubator, OrbiCult
1a. ACI: Chromatography \ Mass Spectrometry: ACI: GC (FID/TCD), 8890N
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
Gas chromatography is a technique used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition.
Agilent Technologies
8890N
Analysis of volatile organic compounds
Flame Ionization Detector (FID) detects organic compounds containing carbon and Thermal Conductivity Detector (TCD) used to detect permanent gases, light hydrocarbons, and compounds that respond poorly to the FID.
Injector: Autosampler, Oven: up to 400°C, Detector: FID/TCD
1a. ACI: Chromatography \ Mass Spectrometry: ACI: GC-MS with Headspace, FID, TCD,
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Gas chromatography is a technique used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition.
Manufacturer: Agilent Techfalselogies
Model Name: 7890A / 5975C
Applications: Analysis of volatile organic compounds
Instrument Overview: Gas chromatography–mass spectrometry (GC-MS) is an analytical method that combines the features of gas-chromatography and mass spectrometry to identify different substances within a test sample
Technical features and specifications:
Oven temperature: 4°C to 450°C
Mass range: 1.6u to 1050u
Charges:
NA
Instrument Manufacturer URL: https://www.agilent.com/en/products/gas-chromatography-mass-spectrometry-gc-ms/gc-ms-instruments/5977a-series-gc-msd-system/5975c-series-gc-msd-system
Detailed Specifications:
NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: GC-MSD-TD, GC7890B/MS5977B/UNITY
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Gas chromatography is a technique used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition.
Manufacturer: Agilent Technologies
Model Name: GC7890B/MS5977B/UNITY
Applications: Analysis of volatile organic compounds
Instrument Overview: Thermal Desorption Gas Chromatography Mass Spectrometry (TD-GCMS) works by subjecting the sample to elevated temperatures for a period of time to drive volatile compounds (VOCs) from the sample matrix. The VOCs emitted are then detected by the MS for identification.
Technical features and specifications:
Sample Type: Liquid / Solid
Mass Range: 25 to 750 m/z
TD Temp: 35 to 425°C
Charges: NA
Instrument Manufacturer URL:
https://markes.com/thermal-desorption-instrumentation
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: HPLC 1 (DAD/Fraction Collector), 1260
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Liquid chromatography is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture.
Manufacturer: Agilent Technologies
Model Name: 1100 series
Applications: Analysis of non-volatile organic compounds
Instrument Overview: Diode Array Detector (DAD), which is capable of acquiring full UV-Vis spectra for better identification of compound spectral signatures.
Technical features and specifications:
Injector: Autosampler
Oven: up to 80°C
Detector: DAD
Charges: NA
Instrument Manufacturer URL:
https://www.agilent.com/en/product/liquid-chromatography/hplc-systems/analytical-hplc-systems
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: HPLC 2 (DAD), 1290 series
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Liquid chromatography is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture.
Manufacturer: Agilent Technologies
Model Name: 1100 series
Applications: Analysis of non-volatile organic compounds
Instrument Overview: Variable Wavelength Detector (VWD) is a UV detector and has a wavelength range of 190 to 600 nm.
Technical features and specifications:
Injector: Autosampler
Oven: up to 80°C
Detector: VWD
Charges: NA
Instrument Manufacturer URL:
https://www.agilent.com/en/product/liquid-chromatography/hplc-systems/analytical-hplc-systems
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: HPLC 3 (VWD), 1200 series
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Liquid chromatography is a technique in analytical chemistry used to separate, identify, and quantify each component in a mixture.
Manufacturer: Agilent Technologies
Model Name: 1200 series
Applications: Analysis of non-volatile organic compounds
Instrument Overview: Multiple Wavelength Detector (MWD) provides simultaneous detection of up to 8 compound specific wavelengths for optimum selectivity over a UV wavelength range from 190 nm to 950 nm.
Technical features and specifications:
Injector: Autosampler
Oven: up to 80°C
Detector: MWD
Charges: NA
Instrument Manufacturer URL:
https://www.agilent.com/en/product/liquid-chromatography/hplc-systems/analytical-hplc-systems
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: HPLC 4 (DAD), 1200 series
1a. ACI: Chromatography \ Mass Spectrometry: ACI: ICP-OES, 5800
1a. ACI: Chromatography \ Mass Spectrometry: ACI: LC-MS/MS, Q-Exactive Orbitrap
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Liquid chromatography is a technique in analytical chemistry is used to separate individual components in a mixture with identification and quantification of each component through the Orbitrap Mass Spectrometry. Orbitrap is an ion trap mass analyzer consisting of an outer barrel-like electrode and a coaxial inner spindle-like electrode that traps ions in an orbital motion around the spindle.
Manufacturer: Thermo Scientific
Model Name: Q-Exactive Orbitrap
Applications: Analysis of both targeted and non-targeted analytes compounds.
Instrument Overview: HCD cell allows ions pass from the nitrogen-filled C-trap into this multipole collision cell and undergo fragmentation. Afterwards, HCD voltage is increased, and the ions are transferred back to the C-trap, to be injected into the Orbitrap for detection. Quadrupole Orbitrap mass spectrometers enable both targeted and non-targeted screening and characterization. High-resolution, accurate-mass (HRAM) performance advantages offered by Orbitrap mass analyzers connect to liquid chromatography equipment to enhance separation of unknown and known compounds and enable high-throughput workflows
Technical features and specifications:
Sample Type: Liquid/ Solid
Mass Range: 50 to 6000m/z
Mass Accuracy: <1ppm
Mass Resolution: > 140000
Scan Speed: 12GHz
Ion Source: ESI/APCI
Charges: NA
Instrument Manufacturer URL:
https://www.thermofisher.com/sg/en/home/industrial/mass-spectrometry/liquid-chromatography-mass-spectrometry-lc-ms/lc-ms-systems/orbitrap-lc-ms.html
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Perkin Elmer, ICP-MS, NexION 2000C
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Inductively coupled plasma spectroscopy is an elemental analysis technology capable of detecting most of the periodic table of elements.
Manufacturer: PerkinElmer
Model Name: NexION 2000C
Applications: Elemental analysis
Instrument Overview: Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is a technique to determine low-concentrations and ultra-low-concentrations of elements.
Technical features and specifications:
Sample Type: Liquid / Solid
Mass Range: 6Li to 238U
Detection Limit: ppb to sub-ppt
Charges: NA
Instrument Manufacturer URL:
https://www.perkinelmer.com/product/nexion-2000b-icp-ms-configuration-n8150044
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: PerkinElmer, ICP-OES, Avio200
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Inductively coupled plasma spectroscopy is an elemental analysis technology capable of detecting most of the periodic table of elements.
Manufacturer: PerkinElmer
Model Name: Avio200
Applications: Elemental Analysis
Instrument Overview: Inductively coupled plasma - optical emission spectrometry (ICP-OES) is mainly used for samples with high total dissolved solids (TDS) or suspended solids and is, therefore, more robust for analyzing ground water, wastewater, soil, and solid waste.
Technical features and specifications:
Sample Type: Liquid
Spectral range: 165-900 nm
Resolution: < 0.009 nm @ 200 nm, < 0.027 nm @ 700 nm
Viewing: Axial and Radial
Detection Limit: ppm to sub-ppb
Charges: NA
Instrument Manufacturer URL:
https://www.perkinelmer.com/libraries/BRO_Avio-200-ICP-OES_012729_01
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Q-TOF LC/MS, LC-QTOF 6545B
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Liquid chromatography is a technique in analytical chemistry is used to separate individual components in a mixture with identification and quantification of each component through the Time-Of-Flight Mass Spectrometry.
Manufacturer: Agilent Technologies
Model Name: LC-QTOF 6545B
Applications: Analysis of both targeted and non-targeted analytes compounds.
Instrument Overview: With the Dual AJS ESI source, the nebulizing gas for the reference spray can be switched for high flow or low flow applications. The second sprayer improves the reference mass stability over a wide range of LC conditions. The Q-TOF MS uses a quadrupole (four parallel rods arranged in a square formation), a collision cell, and a time-of-flight unit to produce spectra. Lighter ions accelerate faster down the flight tube to the detector, thus determining the ions’ mass-to-charge ratios.
Technical features and specifications:
Sample Type: Liquid/ Solid
Mass Range: 50 to 10000m/z
Mass Accuracy: <2ppm
Mass Resolution: > 40000
Scan Speed: 4GHz
Ion Source: ESI/APCI
Charges: NA
Instrument Manufacturer URL:
https://www.agilent.com/en/product/liquid-chromatography-mass-spectrometry-lc-ms/lc-ms-instruments/quadrupole-time-of-flight-lc-ms/6545-lc-q-tof
Detailed Specifications: NA
1a. ACI: Chromatography \ Mass Spectrometry: ACI: TOC Analyzer with Total Nitrogen Unit
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Thermo, Centrifuge, Sorvall ST16R
1a. ACI: Chromatography \ Mass Spectrometry: ACI: Viscotek, GPC Max-Advanced - (Aqueous)
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Bruker, Micro-CT, SKYSCAN 1272
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
High-resolution 3D X-ray Microscopy (Micro-CT).
Uses X-rays to create high-resolution cross-section mapping and 3D models of physical samples, without destroying the sample.
Manufacturer: Bruker
Model Name: SKYSCAN 1272
Applications: 3D scan and microstructure reconstruction.
Instrument Overview: High-resolution 3D X-ray Microscopy (Micro-CT).
Uses X-rays to create high-resolution cross-section mapping and 3D models of physical samples, without destroying the sample.
Technical features and specifications:
X-Ray source: 20-100kV,10W, <5µm spot size @ 4W
X-ray detector: 16Mp or 11Mp, 14-bit cooled CCD fiber-optically coupled to scintillator
Max sample size: 75mm in diameter using offset scan (27mm in fast single scan)
Detail detectability: 0.35µm (16Mp) or 0.45um (11Mp) at highest magnification
Charges:
NA
Instrument Manufacturer URL: https://www.bruker.com/en/products-and-solutions/microscopes/3d-x-ray-microscopes/skyscan-1272.html
Detailed Specifications:
https://www.dksh.com/sg-en/products/ins/bruker-skyscan-1272
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Bruker, XRF, S8 TIGER Series
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
XRF is a non-destructive analysis on bulk materials and fluids for material identification and monitoring of elements.
Manufacturer: Bruker
Model Name: S8 Tiger Series
Applications: Qualitative, quantitative, standard-less quantitative analysis of mineral, ceramic, cement and rock, petroleum products / additives in polymers & paints / ferrous & non-ferrous alloys / trace metals in alloys & solutions.
Instrument Overview: Sample can be analysed in sample cup or pressed as pellet before placed in sample holder. The sample holder will be placed for analysis by autosampler. The X-ray tube will irradiate with primary X-ray beam and emit secondary X-ray (Fluorescence) beam during analysis.
Technical features and specifications:
Wavelength dispersive, Rh-target X-ray tube, WD mapping option. Element range from Beryllium to Uranium
High resolution and high intensity element mapping with 0.3mm and 1.25mm spot (FWHM)
Concentration range: 0.1 to 100%
Reproducibility: +0.1%
Charges: NA
Instrument Manufacturer URL:
https://www.bruker.com/en/products-and-solutions/elemental-analyzers/xrf-spectrometers.html
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Bruker/Anton-Paar, XRD, D8 Advance A25/XRK900
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
XRD is primarily used for phrase identification of crystalline materials and provide information on unit cell dimensions.
Manufacturer: Bruker
Model Name: D8 Advance A25/XRK900
Applications: Qualitative and quantitative phrase analysis, micro-structure analysis, non-ambient powder diffraction.
Instrument Overview: Sample is prepared onto sample holder and placed onto sample tray where it will be picked up to be placed on platform for analysis. Phrase identification and unit cell dimension can be interpreted from the result.
Technical features and specifications:
X-ray source is CuKα
Operating position: vertical
Step width: 0.0001°
Angular range of theta and 2-theta: 360°
Reproducibility of angle setting (theta and 2-theta): < +/- 0.0005°
Absolute accuracy (theta and 2-theta): < +/- 0.005°
Charges: NA
Instrument Manufacturer URL:
https://www.bruker.com/en/products-and-solutions/diffractometers-and-scattering-systems/x-ray-diffractometers.html
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Cressignton, Gold Sputter Coater
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: FE-SEM with EDX, JSM7900FLV/X-Max80
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Scanning Electron Microscopy (SEM) is a high-resolution technique that allows investigations on nanometer-scale surface about a material. SEM uses a focused scanned electron beam and various detectors to collect signals produced by electron-matter interactions from sample surface.
Manufacturer: JEOL/Oxford
Model Name: JSM7900FLV/X-Max80
Applications: Topography: The surface features of an object and its texture Morphology: The shape and size of the particles making up the object Compositional: Elements and compounds and relative amounts.
Instrument Overview: JSM-7900F combines ultra-high resolution imaging with various functions such as GentleBeam, Low Vacuum and Energy Dispersive X-Ray Spectroscopy (EDS).
Technical features and specifications:
Resolution: 0.6nm (15kV), 0.7nm (1kV), 1.0nm (0.5kV)
Magnification: 25 to 1,000,000 (direct)
Accelerating voltage: 0.01 to 30kV
Probe Current: Few pA to 500nA
Electron gun: In-lens Schottky Plus field emission
Detectors: Upper Electron Detector (UED), Lower Electron Detector (LED), Retractable BE Detector (RBED) Low Vacuum Function (LV) / GentleBeam (GBSH) EDS Detector Resolution of 129eV (X-Max80)
Charges: NA
Instrument Manufacturer URL:
https://www.jeol.co.jp/en/products/detail/JSM-7900F.html
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: FE-TEM with EDS/EELS/Cryo, JEM2200FS
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Transmission Electron Microscopy (TEM) is an advanced microscopy technique that allows increased understanding of material properties where details down to nanoscale and atomic level can be revealed.
Manufacturer: JEOL/Gatan
Model Name: JEM2200FS
Applications: JEOL JEM-2200FS in ICES is an analytical grade transmission electron microscope (TEM) that allows elemental and chemical analyses of specimens. It can obtain TEM point resolution of 0.23 nm / lattice resolution of 0.1 nm, and STEM resolution of 0.20 nm at 200 kV. Zero-loss images and energy filtered images are also obtainable using its built-in omega energy filter to provide valuable research information. TEM is capable of studying for nanoparticles, protein complexes, liposomes, ultra-thin sections of cells and tissues. It is equipped with 200kV field emission gun (FEG), high resolution (HR) pole piece, in-column omega energy filter, JED-SDD100 EDS detector (100mm2 sensor size), cryogenic holder and full suite of tomography controls and reconstruction software. In addition, user can also make use of this system to acquire TEM images, high angle annular dark field (HAADF) STEM images, bright field STEM images, 3D tomography TEM/STEM images. Specimen that need cryogenic temperature condition for observation is also available.
Instrument Overview: JEOL JEM-2200FS system is coupled with various analytical capabilities that range from Cryo-EM technique, Energy-dispersive X-ray spectroscopy (EDS) analysis, 3D tomography for both TEM/STEM images and elemental maps, and an in-column omega energy filter for electron energy-loss spectroscopy (EELS). It has a TEM point resolution of 0.23nm, lattice resolution of 0.1nm and STEM resolution of 0.20 nm at 200kV.
Technical features and specifications:
JEM-2200FS
200kV field emission gun (FEG)
In-column omega energy filter (EF-TEM & EELS) with resolution of 0.8eV at 200kV
3D Tomography for TEM/STEM images (Tilt range ±70 degrees)
Degas temp. range: Ambient to 300°C, ± 10°C
High resolution (HR) pole piece
JED-2300
JED-2300 SDD EDS detector (100mm2 sensor size)
Maximum resolution 133eV
Elements detectable to Beryllium
3D tomography of elemental maps
Gatan 690 Elsa ULP
Elsa Cryo-Transfer Holder (High-Tilt)
Charges: NA
Instrument Manufacturer URL:
https://www.jeol.co.jp/en/products/detail/JEM-2200FS.html
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: FEI, Vitrobot Mark IV, FP5350
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: General EQPT: Electric Fluxer, K1 Prime
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: General EQPT: Retsch, Mixer Mill, MM400
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Ion Beam Cross-Sectional and Milling System
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: JEOL, Hydrophilic Treatment Device
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: JEOL, Platinum Sputter Coater
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Park Systems, Atomic Force Microscope, NX-10
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
AFM is a type of scanning probe microscopy technique that uses a probe (cantilever) to measure interactions between its fine tip with surface to provide details on three-dimensional topography or surface features.
Manufacturer: Park Systems
Model Name: NX-10
Applications: Surface imaging of materials under ambient or controlled environment / Drug interactions measurements In-situ observation of drug crystals growth / Microscopic imaging of fragile biological samples Imaging of sub-micron phases in materials / Nano-indentation for mechanical properties
Instrument Overview: The AFM system with an acoustic enclosure provides high resolution, non-destructive imaging on material surfaces with details down to molecular level. It analyses the interaction between particles and reveals surface forces that determine the bulk rheological behavior.
Technical features and specifications:
Z Scanner, AFM/SICM head (scan range): 15um
XY Scanner (scan range): 50um x 50um
Resolution: 0.05nm
Sample size: 100mm x 100mm
Thickness up to 20mm
sample weight < 500g
Field-of-view: 480um x 360um (10x objective lens)
CCD: 1 M pixel
Charges: NA
Instrument Manufacturer URL:
https://www.parksystems.com/products/small-sample-afm/park-nx10/overview
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Rigaku Oxford Diffraction, SC-XRD, SuperNova
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Single crystal X-ray diffraction employs X-ray to determine actual arrangement of atoms within crystalline specimen.
Manufacturer: Rigaku Oxford Diffraction
Model Name: Supernova
Applications: Crystal structure analysis. Provides solution for determination of space group, unit cell, structural refinement, molecular illustrations.
Instrument Overview: Crystallinity has to be present in the sample for analysis in order for X-rays to determine the arrangement of atoms during analysis.
Technical features and specifications:
Microfocus X-ray source: MoKα, CuKα
Detector: Atlas CCD
4-axis KAPPA goniometer
2θ angle range: -180 to +215°
Charges: NA
Instrument Manufacturer URL:
https://www.rigaku.com/products/crystallography
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Thermo Scientific INEL, XRD, Equinox 3000
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Measures all diffraction peaks simultaneously with facilitation of kinetic studies.
Manufacturer: Thermo Scientific
Model Name: Equinox 3000
Applications: Research grade diffractometer suitable for research / environment / geology, cement, mining / metallurgy / pharmaceutical / education.
Instrument Overview: A high resolution diffraction system which has curved detector measuring all diffraction peaks. With a curved detector, the free space in sample compartment is large and is able to accomodate any sample and any sampling device including furnaces, autosamplers, large assemblies etc.
Technical features and specifications:
X-ray tube: Cu
Detector Curvature radius: 250 mm
Acquisition in real time over 120° 2theta
Reflection or transmission mode
Sample changer: 6 or 30 positions
Charges: NA
Instrument Manufacturer URL:
https://www.thermofisher.com/search/browse/category/us/en/90207153/x-ray+diffraction+analyzers
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Thermo Scientific, XPS, ESCALAB 250
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
A sensitive technique to investigate elemental composition and associated chemical bonding states of near-surface region of sample.
Manufacturer: Thermo Scientific
Model Name: ESCALAB 250
Applications: Elemental identification except for H. Chemical state identification and quantification. Resolve interfaces and overlapping peaks. Depth profiling and oxide thickness measurements.
Instrument Overview: The sample is prepared and placed in XPS for analysis on elemental composition and chemical bonding states of the surface region. It can be configured with XPS, AES, SEM and UPS features to extract maximum amount of information from analysis.
Technical features and specifications:
High speed acquistion, maximum chemical detectability
1Mcps in normal operating conditions, (0.6eV at FWHM, Ag sample), <3um chemical imaging resolution
95um spot size at 5nA for Auger analysis
Source defined small area from >650um to <120um, lens defined small area down to <20um
Charges: NA
Instrument Manufacturer URL:
https://www.thermofisher.com/search/browse/category/us/en/90207161/x-ray+photoelectron+spectrometers
Detailed Specifications: NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: ULVAC-PHI, XPS, PHI GENESIS 900
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
X-ray photoelectron spectroscopy (XPS) is a surface-sensitive technique used to analyze the elemental composition and chemical state of materials.
ULVAC-PHI
PHI GENESIS 900
The XPS application areas include: • Catalysis: investigation of catalyst surfaces and active sites to understand reaction mechanisms and improve catalytic performance • Material Science: Characterization of surface chemistry, composition, and electronic properties • Semiconductor: Analysis of thin films, interfaces for process optimization • Nanotechnology: Study of nanoparticles, and nanostructures
The PHI Genesis XPS offers high-resolution spectroscopy for characterizing the elemental composition, chemical states, and electronic properties of surfaces and thin films.
PHI Genesis XPS provides multiple techniques such as, • Monochromatic Al Kα XPS • Monochromatic Cr Kα HAXPES • Non-monochromatic Mg/Al XPS • UPS: ultra-violet photo electron spectroscopy • AES: Auger electron spectroscopy • REELS: Reflection electron energy loss spectroscopy • GCIB: AR gas cluster ion beam • Flow through high pressure reactor chamber, up to 800°C and 10bar
NA
NA
1b. ACI: X-Ray Spectroscopy\Microscopy: ACI: Xenocs, SAXS, Xeuss 2.0
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
SAXS is an analytical instrument to determine the microstructure of particel systems in terms of average particles size or shape.
Manufacturer: Xenocs
Model Name: Xeuss 2.0
Applications: Physical Chemistry and Formulations Polymer and related materials Nanomaterial and biomaterials
Instrument Overview: SAXS is able to deliver structural info of dimension between 10 - 1000Å scale, Determine shape, pore size, interactions and system orders/disorders Useful on studying complex fluids, polymer structure, gels, mesoporous materials, proteins
Technical features and specifications:
System Length: 5 mDetector: Pilatus 300K - Dectris X-ray Source: Micro-focus, Genix3DEnergy: Cu Ka ( λ = 1.541 Å)
Charges:
NA
Instrument Manufacturer URL: https://www.xenocs.com
Detailed Specifications:
NA
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Agilent, Fluorescence Spectrometer
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Agilent, UV-Vis-NIR spectrophotometer
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Anton Paar Rotational Viscometer ViscoQC 100
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Anton Paar UltraTap 500 Tap density meter
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Anton Paar, Refractometer, Abbemat 300
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Anton Paar, Rheometer, MCR 302
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Rheology is used to describe and assess the deformation and flow behavior of materials. Fluids flow at different speeds and solids can be deformed to a certain extent.
Manufacturer: Anton Paar
Model Name: MCR 302
Applications: Long term measurements of sample, Suitable for low viscosity samples, Study flow behavior of fluid samples in response to applied force.
Instrument Overview: Performs a variety of rheological tests, such as rotational, oscillatory, and a combination of both. Measuring systems: cone-plate (with radius R, cone angle α, truncation a); plate-plate (with radius R, distance between plates H); and concentric cylinders (with bob radius Ri and cup radius Re and internal angle α at the tip of the bob).
Technical features and specifications:
Sensitivity: 7.5nNm to 2nNm
Pressure range: Up to 1000 bar
Torque range: 0.5 nNm to 230 mNm (oscillation)
Maximum speed: 3000 1/min
Maximum angular velocity: 314 rad/s (angular)
Normal force range: 0.005-50N
Normal force resolution: 0.5mN
Charges: NA
Instrument Manufacturer URL:
https://www.anton-paar.com/sg-en/products/details/rheometer-mcr-102-302-502/
Detailed Specifications: NA
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Anton Paar, Rheometer, MCR 702
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
Rheology is the study of the flow of matter
Manufacturer: Anton Paar
Model Name: MCR 702
Applications: Polymers, petrochemical additives, foods, personal care products, etc
Instrument Overview: MCR 702 provides rheological measurements using single drive or twin drive. It is able to conduct measurement in various conditions: High pressure, microscope, UV curing.
Technical features and specifications:
With appropriate accessories, MCR 702 can operate/measure at up to the following:
• Torque 0.5 - 230 nNm
• falsermal force range 0.005 - 50 N
• Angular frequency 10-7 - 628 rad/s
• Maximum temperature range -160 - 1000 °C
• Pressure range up to 1 kbar
Charges:
NA
Instrument Manufacturer URL: https://www.anton-paar.com/corp-en/products/group/rheometer/
Detailed Specifications:
NA
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Anton Paar, Viscometer with Density Meter
1c. ACI: NMR\Physical\Thermal Characterisation: ACI: Bruker, FTIR, HYPERION 3000
Institute of Sustainability for Chemicals, Energy and Environment (ISCE²)
1, Pesek Road, Jurong Island, Singapore 627833
What is it?
FTIR is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid or gas. By combining a traditional light microscopy with an FT-IR spectrometer, it allows measuring infrared spectra while obtaining its spatial information.
Manufacturer: Bruker
Model Name: HYPERION 3000
Applications: Research & Development
Polymers and Chemistry
Surface Analysis
Material Science
Pharma and Semiconductors
Instrument Overview: The Hyperion 3000 Microscope performs FT-IR imaging at the highest spatial resolution,with the modern Focal Plane Array(FPA) detector techfalselogy.It boasts an extremelybroad field of applications, including materials research, forensics, art conservation & life sciences.
Technical features and specifications:
High resolution FTIR imaging, With Focal Plane Array (FPA) detectors used, up to 16, 384 spectra can be measured Simultaneously , ATR objective
Charges:
NA
Instrument Manufacturer URL: https://www.bruker.com
Detailed Specifications:
NA